Commit Graph

62 Commits

Author SHA1 Message Date
Julian Metzler f98f531f3e Implemented TranspOtter modifications 2019-11-26 23:58:20 +01:00
EmanuelFeru 9a9eed7d10 Updated current limit
The firmware allows now to set higher currents than 15 A/motor.
NOTE: You can change this limit at your own risk. I do not take any responsability if your boards gets damaged.
2019-11-03 12:45:13 +01:00
EmanuelFeru 01a08d5f6d Fixed ADC calculation
Fix done as suggested in Issue #8 .
2019-11-03 09:54:37 +01:00
EmanuelFeru 62873aad57 PI controller update and fixes
Major:
• all PI controllers with Back-calculation replaced with PI controllers with Clamping to reduce the number of parameters and simplify calculations

Minor:
• fixed the ADC calibration for potetiometer input when ADCx_MIN > 0
• fixed bug: small shock at initialization when current limit I_MOT_MAX is set very small e.g. 1 A
2019-10-31 22:07:52 +01:00
EmanuelFeru 1376793710 Improvements and Issues implementation
Major:
- Issue #3: added raw ADC1, ADC2 values to the setScopeChannel
- Issue #4: added functionality for joystick control. Middle resting potis are now supported (by default it is enabled)
- Issue #6: implemented that board does not power-off after a software reset due to flashing
- added Rate constraints for Input target for smoother response

Minor:
- added 2 beep sound when motors get enabled
- minor bugfixes
2019-10-27 18:21:04 +01:00
EmanuelFeru 1cc8b3475f Visual updates 2019-10-22 21:45:47 +02:00
EmanuelFeru af14b3c4b1 Improved Field Weakening
The performance of the Field Weakening is improved by reducing noise at higher speeds.
2019-10-21 17:51:09 +02:00
EmanuelFeru f991751f68 Added overflow protection
- added aditional protection for fixed-point overflow
- no other functional change
2019-10-20 19:59:16 +02:00
EmanuelFeru 8771742558 Floating-point converted to fixed-point
The follwing were converted to fixed-point
- battery voltage
- board temperature
- filters for steer and speed
- mixer calculation

Starting from this moment, the firmware is floating point free, meaning it runs more efficiently.
2019-10-20 13:31:47 +02:00
EmanuelFeru f6fc825e5f DC Link converted to fixed-point 2019-10-12 19:51:31 +02:00
EmanuelFeru 0527bd770c Added fixed-point low pass filter functions
Preparation of the low pass filter functions. They will be used to replace floating point filters.
2019-10-06 22:43:08 +02:00
EmanuelFeru 5b0b6fecf2 Initial commit 2019-10-06 15:09:15 +02:00