uc: add support for 100A, 250A and 500A CTs
This commit is contained in:
parent
24d8104aac
commit
54283e09b8
75
uc/main.h
75
uc/main.h
|
@ -70,6 +70,81 @@
|
|||
#elif TYPE == 2400503
|
||||
#define METERCONST 5727
|
||||
#warning "240V - 50A - 3-phase selected. METERCONST set to 5727"
|
||||
|
||||
|
||||
#elif TYPE == 2201001
|
||||
#define METERCONST 10598
|
||||
#warning "220V - 100A - 1-phase selected. METERCONST set to 10598"
|
||||
|
||||
#elif TYPE == 2201003
|
||||
#define METERCONST 10502
|
||||
#warning "220V - 100A - 3-phase selected. METERCONST set to 10502"
|
||||
|
||||
#elif TYPE == 2301001
|
||||
#define METERCONST 11080
|
||||
#warning "230V - 100A - 1-phase selected. METERCONST set to 11080"
|
||||
|
||||
#elif TYPE == 2301003
|
||||
#define METERCONST 10978
|
||||
#warning "230V - 100A - 3-phase selected. METERCONST set to 10978"
|
||||
|
||||
#elif TYPE == 2401001
|
||||
#define METERCONST 11560
|
||||
#warning "240V - 100A - 1-phase selected. METERCONST set to 11560"
|
||||
|
||||
#elif TYPE == 2401003
|
||||
#define METERCONST 11454
|
||||
#warning "240V - 100A - 3-phase selected. METERCONST set to 11454"
|
||||
|
||||
|
||||
#elif TYPE == 2202501
|
||||
#define METERCONST 26495
|
||||
#warning "220V - 250A - 1-phase selected. METERCONST set to 26495"
|
||||
|
||||
#elif TYPE == 2202503
|
||||
#define METERCONST 26255
|
||||
#warning "220V - 250A - 3-phase selected. METERCONST set to 26255"
|
||||
|
||||
#elif TYPE == 2302501
|
||||
#define METERCONST 27700
|
||||
#warning "230V - 250A - 1-phase selected. METERCONST set to 27700"
|
||||
|
||||
#elif TYPE == 2302503
|
||||
#define METERCONST 27445
|
||||
#warning "230V - 250A - 3-phase selected. METERCONST set to 27445"
|
||||
|
||||
#elif TYPE == 2402501
|
||||
#define METERCONST 28900
|
||||
#warning "240V - 250A - 1-phase selected. METERCONST set to 28900"
|
||||
|
||||
#elif TYPE == 2402503
|
||||
#define METERCONST 28635
|
||||
#warning "240V - 250A - 3-phase selected. METERCONST set to 28635"
|
||||
|
||||
|
||||
#elif TYPE == 2205001
|
||||
#define METERCONST 52990
|
||||
#warning "220V - 500A - 1-phase selected. METERCONST set to 52990"
|
||||
|
||||
#elif TYPE == 2205003
|
||||
#define METERCONST 52510
|
||||
#warning "220V - 500A - 3-phase selected. METERCONST set to 52510"
|
||||
|
||||
#elif TYPE == 2305001
|
||||
#define METERCONST 55400
|
||||
#warning "230V - 500A - 1-phase selected. METERCONST set to 55400"
|
||||
|
||||
#elif TYPE == 2305003
|
||||
#define METERCONST 54890
|
||||
#warning "230V - 500A - 3-phase selected. METERCONST set to 54890"
|
||||
|
||||
#elif TYPE == 2405001
|
||||
#define METERCONST 57800
|
||||
#warning "240V - 500A - 1-phase selected. METERCONST set to 57800"
|
||||
|
||||
#elif TYPE == 2405003
|
||||
#define METERCONST 57270
|
||||
#warning "240V - 500A - 3-phase selected. METERCONST set to 57270"
|
||||
#endif
|
||||