@ -130,13 +130,13 @@
|
|||
#define DIAG_ENA 1 // [-] Motor Diagnostics enable flag: 0 = Disabled, 1 = Enabled (default)
|
||||
|
||||
// Limitation settings
|
||||
#define I_MOT_MAX 15 // [A] Maximum motor current limit
|
||||
#define I_DC_MAX 17 // [A] Maximum DC Link current limit (This is the final current protection. Above this value, current chopping is applied. To avoid this make sure that I_DC_MAX = I_MOT_MAX + 2A)
|
||||
#define I_MOT_MAX 15 // [A] Maximum single motor current limit
|
||||
#define I_DC_MAX 17 // [A] Maximum stage2 DC Link current limit for Commutation and Sinusoidal types (This is the final current protection. Above this value, current chopping is applied. To avoid this make sure that I_DC_MAX = I_MOT_MAX + 2A)
|
||||
#define N_MOT_MAX 1000 // [rpm] Maximum motor speed limit
|
||||
|
||||
// Field Weakening / Phase Advance
|
||||
#define FIELD_WEAK_ENA 0 // [-] Field Weakening / Phase Advance enable flag: 0 = Disabled (default), 1 = Enabled
|
||||
#define FIELD_WEAK_MAX 5 // [A] Maximum Field Weakening D axis current (only for FOC). Higher current results in higher maximum speed.
|
||||
#define FIELD_WEAK_MAX 5 // [A] Maximum Field Weakening D axis current (only for FOC). Higher current results in higher maximum speed. Up to 10A has been tested using 10" wheels.
|
||||
#define PHASE_ADV_MAX 25 // [deg] Maximum Phase Advance angle (only for SIN). Higher angle results in higher maximum speed.
|
||||
#define FIELD_WEAK_HI 1500 // [-] Input target High threshold for reaching maximum Field Weakening / Phase Advance. Do NOT set this higher than 1500.
|
||||
#define FIELD_WEAK_LO 1000 // [-] Input target Low threshold for starting Field Weakening / Phase Advance. Do NOT set this higher than 1000.
|
||||
|
|