Man kann doch mit den 3Ware-9650SE Raid-Controllern die Smart werte auslesen.
|
||
|
|
||
|
z.b.:
|
||
|
```bash
|
||
|
smartctl -a -d 3ware,<vportID> /dev/twa0
|
||
|
```
|
||
|
|
||
|
Die <vportID> (hier 0-15) kann man über die tw_cli nachschauen, hier mit beispielausgabe:
|
||
|
```bash
|
||
|
# get controller identifier (may change after reboot)
|
||
|
$ sudo tw_cli show
|
||
|
|
||
|
Ctl Model (V)Ports Drives Units NotOpt RRate VRate BBU
|
||
|
------------------------------------------------------------------------
|
||
|
c6 9650SE-16ML 16 16 16 0 4 1 OK
|
||
|
|
||
|
Encls Slots Drives Fans TSUnits PSUnits
|
||
|
-----------------------------------------------------
|
||
|
e0 16 16 8 4 0
|
||
|
|
||
|
# c6 is the controller ID
|
||
|
# lets show all of this controller
|
||
|
$ sudo tw_cli /c6 show
|
||
|
|
||
|
Unit UnitType Status %RCmpl %V/I/M Stripe Size(GB) Cache AVrfy
|
||
|
------------------------------------------------------------------------------
|
||
|
u0 JBOD OK - - - 1863.02 Ri OFF
|
||
|
u1 JBOD OK - - - 1863.02 Ri OFF
|
||
|
u2 JBOD OK - - - 1863.02 Ri OFF
|
||
|
u3 JBOD OK - - - 1863.02 Ri OFF
|
||
|
u4 JBOD OK - - - 1863.02 Ri OFF
|
||
|
u5 JBOD OK - - - 1863.02 Ri OFF
|
||
|
u6 JBOD OK - - - 1863.02 Ri OFF
|
||
|
u7 JBOD OK - - - 1863.02 Ri OFF
|
||
|
u8 JBOD OK - - - 1863.02 Ri OFF
|
||
|
u9 JBOD OK - - - 1863.02 Ri OFF
|
||
|
u10 JBOD OK - - - 1863.02 Ri OFF
|
||
|
u11 JBOD OK - - - 1863.02 Ri OFF
|
||
|
u12 JBOD OK - - - 1863.02 Ri OFF
|
||
|
u13 JBOD OK - - - 1863.02 Ri OFF
|
||
|
u14 JBOD OK - - - 1863.02 Ri OFF
|
||
|
u15 JBOD OK - - - 1863.02 Ri OFF
|
||
|
|
||
|
VPort Status Unit Size Type Phy Encl-Slot Model
|
||
|
------------------------------------------------------------------------------
|
||
|
p0 OK u0 1.82 TB SATA 0 - WDC WD2002FYPS-01U1
|
||
|
p1 OK u1 1.82 TB SATA 1 - WDC WD2003FYYS-02W0
|
||
|
p2 OK u2 1.82 TB SATA 2 - WDC WD2002FYPS-01U1
|
||
|
p3 OK u3 1.82 TB SATA 3 - WDC WD2002FYPS-01U1
|
||
|
p4 OK u4 1.82 TB SATA 4 - WDC WD2002FYPS-01U1
|
||
|
p5 OK u5 1.82 TB SATA 5 - WDC WD2002FYPS-01U1
|
||
|
p6 OK u6 1.82 TB SATA 6 - WDC WD2002FYPS-01U1
|
||
|
p7 OK u7 1.82 TB SATA 7 - WDC WD2002FYPS-01U1
|
||
|
p8 OK u8 1.82 TB SATA 8 - WDC WD2002FYPS-01U1
|
||
|
p9 OK u9 1.82 TB SATA 9 - WDC WD2002FYPS-01U1
|
||
|
p10 OK u10 1.82 TB SATA 10 - WDC WD2002FYPS-01U1
|
||
|
p11 OK u11 1.82 TB SATA 11 - WDC WD2002FYPS-01U1
|
||
|
p12 OK u12 1.82 TB SATA 12 - WDC WD2002FYPS-01U1
|
||
|
p13 OK u13 1.82 TB SATA 13 - WDC WD2002FYPS-01U1
|
||
|
p14 OK u14 1.82 TB SATA 14 - WDC WD2002FYPS-01U1
|
||
|
p15 OK u15 1.82 TB SATA 15 - WDC WD2000FYYZ-01UL
|
||
|
|
||
|
Name OnlineState BBUReady Status Volt Temp Hours LastCapTest
|
||
|
---------------------------------------------------------------------------
|
||
|
bbu On Yes OK OK OK 0 xx-xxx-xxxx
|
||
|
```
|
||
|
die erste Tabelle zeigt alle konfigurierten "Units" an, hier sind alle platten als jbod konfiguriert. \\
|
||
|